Temperature data logger is a product developed by Apresys specifically for the cold chain industry. It is widely used in food, medicine, logistics, blood, chemical, electronics and other industries. After the data recording is completed, the device is plugged into the computer‘s USB interface to read, save, print data.
PDF disposable temperature and humidity data loggeris a product developed by Apresys specifically for the cold chain industry. It is widely used in food, medicine, logistics, blood, chemical, electronics and other industries. After the data recording is completed, the device is plugged into the computer's USB interface, and no software or driver is installed. The data logger will automatically generate a temperature report in PDF format.
Technical Parameter
◆ Temperature range: -30 ° C ~ +70 ° C (-22 ° F ~ 158 ° F)
1. Press and hold the start button for about 3 seconds. The red indicator light flashes 3 times, then flashes 10 times quickly, indicating that the startup is complete.
2. When the PDF data loggeris inserted into the computer, a report in PDF format will be automatically generated. When the data loggeris inserted into the computer, the data logger willstopworking automatically.
Operation Instruction
Status
Action
LED indication
Before starting
Short press button
The indicator will light once
Start
Long press 3-5 s
The indicatorflashes 3times then flashes 10times
Working
Short press button
The light does not flash on working. Short press button, the indicator flashes 10 times quickly
Stop
Short press button
Long light
Note:
1. When placing the data loggerin the test environment, make sure the data loggeris in the startup or start delay state.
2. When the data loggeris plugged into the computer, if the indicator is not lit, check if the USB port is inserted in the opposite direction.
3. Corrosive liquids can damage the equipment and cause it to malfunction. Avoid contact with corrosive objects.
4. The device contains a CR2032 non-rechargeable lithium battery. Do not put the device in a high temperature environment or charge it directly.
5. For long-term effective use of thedata logger, store it at room temperature and keepthe data permanently.
6. Please recycle and dispose of the equipment in accordance with local laws and regulations.